FlowMaster Shake-the-Box and Stereo-PIV System for Large-scale Flow Measurements
(20.11.2020)
LaVisionUK Ltd
2 Minton Place, Victoria Road
OX26 6QB Bicester
FlowMaster Shake-the-Box and Stereo-PIV System for Large-scale Flow Measurements
Danmarks Tekniske Universitet — DTU
Voluntary ex ante transparency notice
Supplies
Directive 2014/24/EU
Section I: Contracting authority/entity
National registration number: 30060946
Postal address: Anker Engelunds Vej 1
Town: Kgs. Lyngby
NUTS code: DK01
Postal code: 2800
Country: Denmark
Contact person: Christian Torrendrup
E-mail: cvto@dtu.dk
Telephone: +45 23100296
Internet address(es):
Main address: http://www.dtu.dk
Section II: Object
FlowMaster Shake-the-Box and Stereo-PIV System for Large-scale Flow Measurements
For research purposes DTU wishes to procure a system that is capable of controlling acquisition and processing images from up to simultaneously 6 high speed cameras into large scale (~m3) volumetric Lagrangean (particle tracking) and Eulerian (correlation based) velocity fields, including the possibility to estimate pressure from the measured velocity fields.
Kgs. Lyngby.
For research purposes DTU wishes to procure a system that is capable of controlling acquisition and processing images from up to simultaneously 6 high speed cameras into large scale (~m3) volumetric Lagrangean (particle tracking) and Eulerian (correlation based) velocity fields, including the possibility to estimate pressure from the measured velocity fields.
Software module (unique) for estimating average pressure fields and a pseudo Lagrangean approach for instantaneous pressure reconstruction.
Section IV: Procedure
- The works, supplies or services can be provided only by a particular economic operator for the following reason:
- absence of competition for technical reasons
LaVision is the only suitable supplier that is able to provide a system that fulfills the unique combination of required specifications:
— LaVision can unlike its competitors, provide measurement systems that are able to fully control and automate measurements of a time-varying flow, including data handling and processing, once the measurement process has been setup and defined. This includes control and automation of acquisition, data transfer and cluster based processing of the measurements into 3D Lagrangean particle tracks and Eulerian correlation based 3D-3C velocity fields, respectively.
— The LaVision software DaVis includes programmable parameter recording for varying the time between individual snapshots across a measurement using a programmable timing unit. Recording at variable framerates within one recording cycle (so-called dual rate recording) is supported in the associated software DaVis. Further, DaVis can correct for the variable delays in the processing,
— The DaVis processing software is unique in the well-published high achievable recorded seeding densities it can process successfully into accurate particle tracking and correlation based velocity fields, respectively:
• The well-established (>10 years in the community) patented tomographic particle image velocimetry algorithm (EP 1 517 150 B1) is a well-proven technique that can retrieve volumetric data from densely seeded flows (>0.1 particles per pixel).
• The patented (EP 3 004 898) volumetric lagrangian particle tracking algorithm, shake-the-box (STB), can retrieve volumetric particle tracking data from densely seeded flows (>0.05 particles per pixel). The patented iterative 3D particle reconstruction technique (EP 2 344 894) used with the STB algorithm allows for measurements with such high spatial seeding densities, that it distinguishes the software from the competition. Furthermore, the iterative particle reconstruction allows STB to be used with 2- and 4-pulse data with high seeding density, which reduces significantly the cost of the laser/light source and provides a high flexibility on the measurement possibilities using the same hardware.
— The patented (EP 1 926 049 B1) volumetric self-calibration that produces a self-correction using disparity maps of the acquired images (calibration error <0.1 pixel) is the gold standard with respect to calibration accuracy. This volumetric self-calibration is used for STB as well as for Tomographic measurements.
— The solution can measure particle tracking in large volumes of the order of cubic meters.
— The software also comes with a unique option (module) for estimating average pressure fields and a pseudo Lagrangean approach for instantaneous pressure reconstruction. For the particle tracks from STB measurements (regardless of the distribution of particles in the measurement domain), a data assimilation-based technique called Fine-Scale Reconstruction (VIC#) is available in the DaVis software, for firstly ensuring that the measured flow adheres to the flow governing equations and intrinsically, pressure evaluation from these results.
These methods are well-documented and well-accepted in the scientific literature.
A complete system for flow measurements from a single supplier is necessary to ensure a functional assembled system and traceable service and insurance conditions.
Section V: Award of contract/concession
Postal address: Minton Place, Victoria Road
Town: Bicester
NUTS code: UK
Country: United Kingdom
Section VI: Complementary information
Postal address: Nævnenes hus, Toldboden 2
Town: Viborg
Postal code: 8800
Country: Denmark
E-mail: klfu@erst.dk
Telephone: +45 35291000
Internet address: http://www.klfu.dk
Complaint regarding the contracting authority’s award of contract without prior publication of a contract notice in the European Union Official Journal must be submitted no later than 30 calendar days from the date after a contract award notice has been published by the contracting authority in the European Union Official Journal and that contract award notice includes the grounds for the decision to award the contract directly, cf. Law regarding Complaints board (in Danish Klagenævnet for Udbud) § 7, section 3.
Postal address: Carl Jacobsens Vej 35
Town: Valby
Postal code: 2500
Country: Denmark
E-mail: kfst@kfst.dk
Telephone: +45 41715000
Internet address: http://www.kfst.dk