23948sdkhjf

Fakta om udbudet

EU-nr
2020/S 227-557662
Offentliggjort
20.11.2020
Udbudstype
Udbud med forhandling uden forudgående offentliggørelse

Udbyder

University of Copenhagen

Vindere

(20.11.2020)
Bruker Nordic AB
Torshmansgatan 44
SE-164 40 Kista

Acquisition of a Timstof Pro LC-MS System (Mass Spectrometer)


University of Copenhagen

Voluntary ex ante transparency notice

Supplies

Legal Basis:
Directive 2014/24/EU

Section I: Contracting authority/entity

I.1) Name and addresses
Official name: University of Copenhagen
Postal address: Nørregade 10
Town: Copenhagen K
NUTS code: DK01 Hovedstaden
Postal code: 1165
Country: Denmark
Contact person: Mahmut Yüksel
E-mail: Fgn253@ku.dk
Internet address(es):
Main address: www.KU.dk
I.4) Type of the contracting authority
Body governed by public law
I.5) Main activity
Education

Section II: Object

II.1) Scope of the procurement
II.1.1) Title:

Acquisition of a Timstof Pro LC-MS System (Mass Spectrometer)

II.1.2) Main CPV code
38433100 Mass spectrometer
II.1.3) Type of contract
Supplies
II.1.4) Short description:

We wish to purchase a timsTOF Pro mass spectrometer with trapped ion mobility which allows Parallel Accumulation Serial Fragmentation (PASEF) acquisition method to provide extremely high speed and sensitivity proteomics. Bruker is the only provider of such instruments.

II.1.6) Information about lots
This contract is divided into lots: no
II.1.7) Total value of the procurement (excluding VAT)
Value excluding VAT: 3 128 450.00 DKK
II.2) Description
II.2.3) Place of performance
NUTS code: DK01 Hovedstaden
II.2.4) Description of the procurement:

We wish to purchase a timsTOF Pro mass spectrometer with trapped ion mobility which allows Parallel Accumulation Serial Fragmentation (PASEF) acquisition method to provide extremely high speed and sensitivity proteomics. Bruker is the only provider of such instruments. The laboratory of Prof. Mann at the Centre for Protein Research, KU and also the Max Planck Institute for Biochemistry, Munich have tested this technology and have demonstrated more than 800 000 fragmentation spectra in standard 120 min LC runs, which can be used for near exhaustive precursor selection in the complex mixtures we examine. Online PASEF achieves remarkable sensitivity with more than 2 900 proteins identified in 30 min runs with 10 ng of material. This technology is essential for our research.

II.2.5) Award criteria
II.2.11) Information about options
Options: no
II.2.13) Information about European Union funds
The procurement is related to a project and/or programme financed by European Union funds: no
II.2.14) Additional information

Section IV: Procedure

IV.1) Description
IV.1.1) Type of procedure
Negotiated procedure without prior publication
  • The works, supplies or services can be provided only by a particular economic operator for the following reason:
    • protection of exclusive rights, including intellectual property rights
Explanation:

1) The instrument must be able to synchronise the quadrupole with the IMS elution time to allow for a high MS/MS acquisition speed, leading to an increased fragmentation depth and there must be algorithms for intelligent targeting of low-level precursors.

2) The MS instrument must be capable of real-time data acquisition and processing, enabling a high spectrum repetition rate of > 100 Hz in MS/MS mode (including ion mobility separation and without sacrificing sensitivity) to obtain highest possible identification of both peptides and proteins, i.e. high sequence coverage of the identified proteins.

3) Mass resolution 60 000 independent of MS or MS/MS sequencing speed.

4) Reproducibility of Collisional Cross Section (CCS) value determination < 0.5 % RSD.

5) Pre-defined methods for DDA, DIA, PRM delivered, where both m/z and ion mobility are used for selectivity (i.e. window selection in DIA and PRM, and possibility to integrate various LC vendors into the instrument control software and the data-file format must be open architecture to enable easy input for various bioinformatics approaches.

The timsTOF Pro system comes with a dual-TIMS (trapped ion mobility spectrometry) analyser optimised for high-speed shotgun proteomics. It has nearly 100 % duty cycle, making this parallel accumulation serial fragmentation technique (PASEF) perfectly suited for nanoflow LC-MS analysis of enzymatically-digested complex protein mixtures. The timsTOF Pro from Bruker is the only instrument in the market that has TIMS technology allowing PASEF, DIA-PASEF and PRM-PASEF acquisition methods.

Patent:

TIMS

— TIMS cell

Title: ‘Apparatus and method for parallel flow ion mobility spectrometry combined with mass spectrometry’

Issued: US7838826B1; US 8288717B2

— IMEX, temporal zoom

Title: ‘Spectrum Acquisition Modes For Ion Mobility Spectrometers Using Trapped Ions’

Issued: US8766176B2; GB2490387B

Pending: DE102012004398A1

— Parallel Accumulation TIMS

Ion Guide System:

— High Precision Multipole Rod Ion Guides

Title: ‘Multiple rod systems produced by wire erosion’

Issued: DE102004037511B4; GB2416915B; US7351963B2

— Ion Beam Conditioning

Title: ‘Conditioning of an ion beam for injection into a time-of-flight mass spectrometer’

Issued: GB2361803B; US6700117B2

TOF Mass Analyser:

Gridless Orthogonal Accelerator and Ion Optics for Focus Mode

Title: ‘Gridless time-of-flight mass spectrometer for orthogonal ion injection’

Issued: DE10005698B4; GB2361353B; US6717132B2

Title: ‘Pulsers for time-of-flight mass spectrometers with orthogonal ion injection’

Issued: DE10158924B4; GB2386751B; US6903332B2

— Reflector Design

Title: ‘Reflectors for time-of-flight mass spectrometers’

Issued: DE102014009900B4; CN105244242B

Pending: GB2530840A; US20160005583A1

— Auto-Calibration of Detector

Title: ‘Method of adjusting the detector amplification in mass spectrometers’

Issued: DE102008010118B4; GB2457559B; US8536519B2

— Advanced Mass Band-Width

Title: ‘Method of operating a time-of-flight mass spectrometer with orthogonal ion pulsing’

Issued: DE102011100525B4; GB2490577B; US8927928B2

Electro-Spray Ion Source with Ion Funnel

Title: ‘Ion guide for mass spectrometers’

Issued: CA2463433C; CA2747956C; US7495212B2; US7851752B2; US8222597B2; EP1465234B1 (DE, GB)

Title: ‘Ion funnel with improved ion screening’

Issued: GB2402261B; US7064321B2.

IV.1.3) Information about framework agreement
IV.1.8) Information about the Government Procurement Agreement (GPA)
The procurement is covered by the Government Procurement Agreement: yes
IV.2) Administrative information

Section V: Award of contract/concession

V.2) Award of contract/concession
V.2.1) Date of contract award decision:
09/11/2020
V.2.2) Information about tenders
The contract has been awarded to a group of economic operators: no
V.2.3) Name and address of the contractor/concessionaire
Official name: Bruker Nordic AB
Postal address: Torshmansgatan 44
Town: Kista
NUTS code: SE SVERIGE
Postal code: SE-164 40
Country: Sweden
E-mail: Peter.abrahamsson@bruker.com
Telephone: +46 86552500
Internet address: www.bruker.com
The contractor/concessionaire will be an SME: no
V.2.4) Information on value of the contract/lot/concession (excluding VAT)
Total value of the contract/lot/concession: 3 128 450.00 DKK
V.2.5) Information about subcontracting

Section VI: Complementary information

VI.3) Additional information:
VI.4) Procedures for review
VI.4.1) Review body
Official name: Danish Public Contracts Appeal Board
Postal address: Nævnenes hus, toldboden 2
Town: Viborg
Postal code: 8800
Country: Denmark
E-mail: NH@naevneneshus.dk
Telephone: +45 72405600
Internet address: www.KLFU.dk
VI.5) Date of dispatch of this notice:
16/11/2020

Send til en kollega

0.047