23948sdkhjf
Log ind eller opret et abonnement for at gemme artikler
Få adgang til alt indhold på Electronic Supply
Annonce
Annonce

Fakta om udbudet

EU-nr
Offentliggjort
16.09.2025
Udbudstype
Andre

Udbyder

Danmarks Tekniske Universitet - DTU

Gradient Power Amplifier System


Danmarks Tekniske Universitet - DTU

604726-2025 - Direct award preannouncement
Denmark – Scanners – Gradient Power Amplifier System
OJ S 177/2025 16/09/2025
Voluntary ex-ante transparency notice
Supplies
1. Buyer
1.1.
Buyer
Official name Danmarks Tekniske Universitet - DTU
Email perach@dtu.dk
Legal type of the buyer Body governed by public law
Activity of the contracting authority Education
2. Procedure
2.1.
Procedure
Title Gradient Power Amplifier System
Description DTU needs to purchase 2 separate amplifiers with power supply units, each suited for driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. To compensate for the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers must sustain peak voltages >1000 V and peak currents >260 A (at 20 kHz: >1000 V and >130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers needs to be designed, built and equipped with safety measures so it can be approved for clinical use, even though CE labelling is not a requirement. Market research has shown that the only supplier of suitable gradient amplifiers that can fulfill the requirements above is IECO. Therefore, DTU intends to issue a purchase order to the company.
Procedure identifier 469d8170-ce61-467b-b47e-17d7f753757d
Internal identifier 10316
Type of procedure Negotiated without prior call for competition
2.1.1.
Purpose
Main nature of the contract Supplies
Main classification   ( cpv ):  38520000   Scanners
2.1.2.
Place of performance
Anywhere
2.1.4.
General information
Additional information A market survey was conducted using web search, AI queries and literature review. To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must sustain peak voltages >1000 V and peak currents >260 A (at 20 kHz: >1000 V and >130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%) during the lifetime of the carbon MRI signal, i.e., . 2 minutes. No vendor of MRI gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore, DTU intends to issue the purchase order to the company.
Legal basis
Directive 2014/24/EU
5. Lot
5.1.
Lot LOT-0000
Title Gradient Power Amplifier System
Description DTU needs to purchase 2 separate amplifiers with power supply units, each suited for driving a uniaxial head insert gradient coil (60-70 micro-Henry) for animal and human magnetic resonance imaging (MRI), particularly for strongly accelerated hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. To compensate for the low gyromagnetic ratio of carbon-13, for a 10 kHz sinusoidal gradient, the amplifiers must sustain peak voltages >1000 V and peak currents >260 A (at 20 kHz: >1000 V and >130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI. The maximum duty cycle needs to be high (preferably 100% at 10 kHz) during the lifetime of the carbon MRI signal, i.e., 2 minutes. At least one of the amplifiers needs to be designed, built and equipped with safety measures so it can be approved for clinical use, even though CE labelling is not a requirement. Market research has shown that the only supplier of suitable gradient amplifiers that can fulfill the requirements above is IECO. Therefore, DTU intends to issue a purchase order to the company.
Internal identifier 10316
5.1.1.
Purpose
Main nature of the contract Supplies
Main classification   ( cpv ):  38520000   Scanners
Quantity 2   pieces
5.1.2.
Place of performance
Anywhere
5.1.6.
General information
The procurement is covered by the Government Procurement Agreement (GPA) yes
Additional information A market survey was conducted using web search, AI queries and literature review. To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must sustain peak voltages >1000 V and peak currents >260 A (at 20 kHz: >1000 V and >130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%) during the lifetime of the carbon MRI signal, i.e., . 2 minutes. No vendor of MRI gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore, DTU intends to issue the purchase order to the company.
5.1.16.
Further information, mediation and review
Mediation organisation Konkurrence- og Forbrugerstyrelsen
Review organisation Klagenævnet for Udbud
Organisation providing more information on the review procedures Danmarks Tekniske Universitet - DTU
6. Results
Value of all contracts awarded in this notice 80 000,00   EUR
Direct award
Justification for direct award The contract can be provided only by a particular economic operator because of an absence of competition for technical reasons
Other justification A market survey was conducted using web search, AI queries and literature review. To compensate for the low gyromagnetic ratio of carbon-13, essentially 4 times more gradient output is required compared to hydrogen MRI. At 10 kHz, the amplifier must sustain peak voltages >1000 V and peak currents >260 A (at 20 kHz: >1000 V and >130 A). Arbitrary waveforms up to 20 kHz must be suited for normal high-performance MRI with non-resonant gradients. The maximum duty cycle needs to be high (preferably 100%) during the lifetime of the carbon MRI signal, i.e., 2 minutes. No vendor of MRI gradient amplifiers can provide the needed output at 10 and 20 kHz except IECO. Therefore, DTU intends to issue the purchase order to the company.
6.1.
Result lot identifier LOT-0000
6.1.2.
Information about winners
Winner
Official name International Electric Company Oy
Tender
Tender identifier 10316 Gradient Power Amplifier System
Identifier of lot or group of lots LOT-0000
Contract information
Identifier of the contract 10316 Gradient Power Amplifier System
8. Organisations
8.1.
ORG-0001
Official name Danmarks Tekniske Universitet - DTU
Registration number 30060946
Postal address Anker Engelunds Vej 1
Town Kgs. Lyngby
Postcode 2800
Country subdivision (NUTS) Københavns omegn  ( DK012 )
Country Denmark
Contact point Per Christiansen
Email perach@dtu.dk
Telephone +45 45252525
Internet address https://www.dtu.dk
Roles of this organisation
Buyer
Organisation providing more information on the review procedures
8.1.
ORG-0002
Official name Klagenævnet for Udbud
Registration number 37795526
Postal address Nævnenes hus, Toldboden 2
Town Viborg
Postcode 8800
Country subdivision (NUTS) Østjylland  ( DK042 )
Country Denmark
Email klfu@erst.dk
Telephone +45 35291000
Internet address http://www.klfu.dk
Roles of this organisation
Review organisation
8.1.
ORG-0003
Official name Konkurrence- og Forbrugerstyrelsen
Registration number 10294819
Postal address Carl Jacobsens Vej 35
Town Valby
Postcode 2500
Country subdivision (NUTS) Byen København  ( DK011 )
Country Denmark
Email kfst@kfst.dk
Telephone +45 41715000
Internet address http://www.kfst.dk
Roles of this organisation
Mediation organisation
8.1.
ORG-0004
Official name International Electric Company Oy
Registration number FI2189657-1
Postal address Saahaajankatu 48
Town Helsinki
Postcode 00880
Country subdivision (NUTS) Helsinki-Uusimaa  ( FI1B1 )
Country Finland
Contact point Pasi Honkanen
Email info@ieco.fi
Telephone +35897594470
Roles of this organisation
Tenderer
Winner of these lots LOT-0000
8.1.
ORG-0005
Official name Mercell Holding ASA
Registration number 980921565
Postal address Askekroken 11
Town Oslo
Postcode 0277
Country subdivision (NUTS) Oslo  ( NO081 )
Country Norway
Contact point eSender
Telephone +47 21018800
Fax +47 21018801
Internet address http://mercell.com/
Roles of this organisation
TED eSender
Notice information
Notice identifier/version d4222e47-1291-43bc-aec8-9ae47298833d   -   01
Form type Direct award preannouncement
Notice type Voluntary ex-ante transparency notice
Notice subtype 25
Notice dispatch date 15/09/2025   09:39:39 (UTC) Western European Time, GMT
Notice dispatch date (eSender) 15/09/2025   11:00:47 (UTC) Western European Time, GMT
Languages in which this notice is officially available English
Notice publication number 604726-2025
OJ S issue number 177/2025
Publication date 16/09/2025