SPM Probe VT STM XA 100-500 Q plus with Matrix
DTU need an ultra-high vacuum system equipped with a scanning probe microscope. This system will be used for synthesis of thin films and nanomaterials (for instance, but not limited to, two-dimensional materials, metallic thin films, molecular assembly) and in situ characterization of their structural and electronic properties with scanning probe microscopy techniques (scanning tunneling microscopy/scanning tunneling spectroscopy, and atomic force microscopy).
DTU need an ultra-high vacuum system equipped with a scanning probe microscope. This system will be used for synthesis of thin films and nanomaterials (for instance, but not limited to, two-dimensional materials, metallic thin films, molecular assembly) and in situ characterization of their structural and electronic properties with scanning probe microscopy techniques (scanning tunneling microscopy/scanning tunneling spectroscopy, and atomic force microscopy).
Section IV: Procedure
- The works, supplies or services can be provided only by a particular economic operator for the following reason:
- absence of competition for technical reasons
DTU needs to acquire an ultra-high vacuum system equipped with a scanning probe microscope (SPM). There are multiple suppliers in the market but only Scienta Omnicron can deliver a ultra-high vacuum system that has the below mentioned specifications which are needed to perform the re-search in question. The needed specifications are:
— a fast entry chamber for sample loading without breaking vacuum in the SPM chamber,
— sample preparation (that is, sample cleaning and deposition of other elements).
The scanning probe microscope must have the following capabilities:
— working both as a scanning tunneling microscope (STM) and a non-contact AFM with small oscillation amplitudes for high resolution imaging,
— Tip motion in X, Y and Z of at least 10 mm x 10 mm x 10 mm,
— Scan range of 12μm x 12μm x 1.5μm (X, Y and Z),
— In situ evaporation and tip coarse position with sub-micrometer precision for in situ material growth also during imaging,
— In situ tip exchange,
— Capability of imaging in the range of at least 100 K to 500 K.
Section V: Award of contract/concession
DE 111 361 420
Limburger Str. 75
Taunusstein
65232
Germany
E-mail: ad.ettema@scientaomicron.com
NUTS code: DE
Internet address: www.scientaomicron.com
Section VI: Complementary information
Nævnenes Hus, Toldboden 2
Viborg
8800
Denmark
Telephone: +45 35291000
E-mail: klfu@erst.dk
Internet address: https://erhvervsstyrelsen.dk/klagenaevnet-for-udbud
Carl Jacobsensvej 35
Valby
2500
Denmark